SLVK147A August   2023  – September 2023 TPS7H2201-SEP

PRODUCTION DATA  

  1.   1
  2.   Trademarks
  3. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  4. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Test Configuration and Condition
  5. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 TPS7H2201-SEP Specification Compliance Matrix
  6. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  7. 5Revision History
  8.   A Appendix: HDR TID Report Data

Test Configuration and Condition

HDR devices were stressed at 20 krad(Si), 30 krad(Si) and 50 krad(Si) for biased and unbiased conditions.

Table 2-2 HDR 20 krad(Si), 30 krad(Si) and 50 krad(Si) Biased Device Information
Total Samples: 15
Exposure Levels
20 krad(Si)30 krad(Si)50 krad(Si)
6, 7, 8, 9, 1016, 17, 18, 19, 2026, 27, 28, 29, 30
Table 2-3 HDR 20 krad(Si), 30 krad(Si) and 50 krad(Si) Unbiased Device Information
Total Samples: 15
Exposure Levels
20 krad(Si)30 krad(Si)50 krad(Si)
1, 2, 3, 4, 511, 12, 13, 14, 1521, 22, 23, 24, 25