TID Characterization Summary Results

The parametric data for the TPS7H2211-SEP passes up to 50-krad(Si) HDR TID irradiation. The drifts of the electrical parameters through HDR were within the data sheet limits.

Overall, the TPS7H2211-SEP showed a strong degree of hardness to HDR TID irradiation up to 50 krad(Si) for biased exposure conditions. The measurements taken post-irradiation for each sample set showed a marginal shift for most parameters at each dose level. The parameters that did show a greater degree of change between pre- and post-irradiation were still within the electrical performance characteristics specified in the data sheet electrical parameters. See Section 3.2 below for parameters and associated tests.

See Appendix A for HDR report up to 50 krad(Si).