SLVK152B August 2023 – November 2023 TPS7H2140-SEP
PRODUCTION DATA
The results show that all devices were fully functional and within specification limits up to 30 krad(Si) for HDR and LDR TID.
Overall, the TPS7H2140-SEP showed a strong degree of hardness to HDR and LDR TID irradiation up to 30 krad(Si) for both biased and unbiased exposure conditions. The measurements taken post-irradiation for each sample set showed a marginal shift for most parameters at each dose level for both biased and unbiased. The parameters that did show a greater degree of change between pre- and post-irradiation were still within the data sheet electrical specifications (see Section 3.2 for the data sheet electrical parameters table).
See Appendix A for HDR report up to 30 krad(Si).
See Appendix B for LDR report up to 30 krad(Si).