SLVSDU6D July 2017 – November 2019
PRODUCTION DATA.
In order for ATL43xLI to properly be used as a control component in this circuit, the minimum operating current needs to be reached. This is accomplished by setting the external biasing resistor in series with the ATL43xLI.
For ATL43xLI, the minimum operating current is 80µA and with margin consideration, most of the designs set this current to be higher than 100µA. To achieve lower power consumption, please consider devices such as ATL43x.