The TPS53219EVM-690 contains a 10-Ω series
resistor in the feedback loop for loop response analysis.
- Set up EVM as described in Section 4 and Figure 4-2.
- Connect an isolation transformer to test points
marked TP9 and TP10.
- Connect a input signal amplitude measurement
probe (channel A) to TP9. Connect output signal amplitude measurement probe (channel B) to
TP10.
- Connect ground lead of channel A and channel B to TP11.
- Inject approximately 40-mV or less signal through the isolation transformer.
- Sweep the frequency from 100 Hz to 1 MHz with 10 Hz or lower post filter. The control loop gain and phase margin can be measured.
- Disconnect isolation transformer from bode plot
test points before making other measurements (signal injection into feedback can interfere
with accuracy of other measurements).