SLVU570A September   2011  – May 2021 TPS652510

 

  1.   Trademarks
  2. 1Background and EVM Limitations
  3. 2Power-up Procedure
  4. 3TPS652510EVM Schematic
  5. 4EVM Layout
  6. 5Bench Test Setup Conditions
    1. 5.1 Headers Description
    2. 5.2 Test Points and Placement
  7. 6Revision History

Headers Description

Header NumberFunctionLOCPlacementComment
JP11BUCK1 enable (EN1)SWFor immediate start-up fit jumper to V3V
For sequencing do not fit jumper
To disable converter fit jumper to GND
Fit according to test requirement
JP20BUCK2 enable (EN2)SWFor immediate start-up fit jumper to V3V
For sequencing do not fit jumper
To disable converter fit jumper to GND
Fit according to test requirement
JP3BUCK3 enable (EN3)SWFor immediate start-up fit jumper to V3V
For sequencing do not fit jumper
To disable converter fit jumper to GND
Fit according to test requirement
JP25Forced PWM (F_PWM)SFor forced PWM operation fit jumper to V3V
For automatic PFM/PWM operation fit jumper to GND
Do not leave this header open. Use a jumper to set either forced PWM mode or automatic PFM/PWM mode
JP26TestSUsed for test purposesJumper must be fitted
JP27PGOODSPGOOD indicated pulled to 3V3Fit according to test requirement