SLVU777A September 2012 – November 2021 TPS54020
The slow-start time is adjusted by changing the value of C14. Use Equation 2 to calculate the required value of C14 for a desired slow-start time.
Where:
TSS = desired slow start time
ISS = slow start charging current = 2.3-µA nominal
VREF = 0.6-V reference voltage
The EVM is set for a slow-start time of approximately 26 ms using C14 = 0.1 μF.