SLVUC15 March   2021 TPS7H4001-SP

 

  1.   1
  2.   2
    1.     3
    2.     4
  3.   5
    1.     6
    2.     7
  4.   8
    1.     9
    2.     10

Model Parameters

The following parameters are used within the model to define the internal characteristics, operating environment, and configuration of the device.

Parameter Description Default Model Value
Mean_GMea The mean value of the error amplifier transconductance 1800 µS
Mean_GMps The mean value of the power stage transconductance 40 S
Mean_Vref The mean value of the reference voltage 0.605 V
Tol_GMea The tolerance of the error amplifier transconductance [1] 8.72 %
Tol_GMps The tolerance of the power stage transconductance [1] 5.22 %
Tol_Vref The tolerance of the reference voltage [1] 0.31 %
TID The Total Ionizing Dose the device is subjected to, within the range of 0 to 100 krad 0 krad
AGING

Binary value indicating the presence of aging effects, where:

0 = No aging effects added

1 = Aging effects added

0

L Output inductor value 0.9 µF
FS Switching frequency 500 kHz
TEMP Operating temperature, which is set within the simulation profile and takes the default value unless otherwise specified. 27°C

[1] For Gaussian distributions, tolerance is defined as the standard deviation (1-sigma) divided by the mean and is expressed as a percentage.