SLVUCD2 January   2022 TPS65917-Q1

 

  1.   Trademarks
  2. 1Introduction
  3. 2BOOT OTP Configuration
  4. 3Static Platform Settings
    1. 3.1 System Voltage Monitoring
    2. 3.2 SMPS
    3. 3.3 LDO
    4. 3.4 Interrupts
    5. 3.5 GPIO
    6. 3.6 MISC
    7. 3.7 SWOFF_HWRST
    8. 3.8 Shutdown_ColdReset
  5. 4Sequence Platform Settings
    1. 4.1 OFF2ACT Sequences
    2. 4.2 ACT2OFF Sequences

SMPS

This section describes the default voltage for each SMPS.

Table 3-2 SMPS OTP Settings
BIT DESCRIPTION OTP VALUE UNIT
SMPS1_VOLTAGE Default output voltage for the regulator 1.10 V
SMPS2_VOLTAGE Default output voltage for the regulator 1.10 V
SMPS3_VOLTAGE Default output voltage for the regulator 1.10 V
SMPS4_VOLTAGE Default output voltage for the regulator 1.80 V
SMPS5_VOLTAGE Default output voltage for the regulator 1.10 V
SMPS1_SMPS12_EN SMPS12 single-phase or dual-phase configuration.
0: SMPS1 and SMPS2 single-phase
1: SMPS12 dual-phase
0 NA