When attached to a 100W source the PD controller has RX_SOURCE_CAPS:
- PDO1: 5V at 3A
- PDO2: 9V at 3A
- PDO3: 15V at 3A
- PDO4: 20V at 5A
The PD controller has TX_SINK_CAPS set as:
- PDO1: 5V at 3A (fixed)
- PDO2: 20V at 5A (fixed)
The PD controller has AUTO_NEGOTIATE_SINK set as:
- AUTO_NEGOTIATE_SINK = 0
- AUTO_NEGOTIATE_SINK.ANSinkCapMismatchPower = 240d (60W)
- AUTO_NEGOTIATE_SINK.AutoComputeSinkMinPower = 1
- AUTO_NEGOTIATE_SINK.AutoComputeSinkMinVoltage = 1
- AUTO_NEGOTIATE_SINK.AutoComputeSinkMaxVoltage = 1
- AUTO_NEGOTIATE_SINK.NoCapabilityMismatch = 0
- AUTO_NEGOTIATE_SINK.ANRDOPriority = y (see table below)
The settings give the following results:
- ANSinkMinRequiredPower computed as 100W
- ANMaxVoltage computed as 20V
- ANMinVoltage computed as 4.75V
Table 5-6 AUTO_NEGOTIATE_SINK Usage Example 3.
AUTO_NEGOTIATE_SINK |
ACTIVE_CONTRACT_RDO |
ANRDOPriority |
OperatingX |
MinMaxOperatingX |
ObjectPosition |
Capability Mismatch |
0 |
5A |
5A |
4 |
0 |
1 |
5A |
5A |
4 |
0 |