SLYA036B July 2018 – November 2021 DRV5053 , DRV5053-Q1 , DRV5055 , DRV5055-Q1 , DRV5056 , DRV5056-Q1 , DRV5057 , DRV5057-Q1
The accuracy for this setup depends on the current region and the value of n. When using evenly spaced regions, where n = (180 / s)°, the accuracy for each region is (180 / s). To determine the accuracy when using any other value for n, adapt the method described in Section 4.1.4.3 to adjust for the number of sensors (s) and spacing (n).