SNIU028D February 2016 – September 2020 UCD3138 , UCD3138064 , UCD3138064A , UCD3138128 , UCD3138A , UCD3138A64
Address 00020014
29 | 28 | 27 | 26 | 25 | 24 |
FILTER2_KCOMP_SEL | FILTER1_KCOMP_SEL | FILTER0_KCOMP_SEL |
R/W-00 | R/W-00 | R/W-00 |
23 | 19 | 18 | 17 | 16 |
Reserved | FILTER2_ FFWD_SEL | FILTER1_ FFWD_SEL | FILTER0_ FFWD_SEL |
R-0 0000 | R/W-0 | R/W-0 | R/W-0 |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
Reserved | FILTER2_PER_SEL | FILTER1_PER_SEL | FILTER0_PER_SEL |
R-00 | R/W-00 | R/W-00 | R/W-00 |
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved | FILTER2_FE_SEL | FILTER1_FE_SEL | FILTER0_FE_SEL |
R-00 | R/W-10 | R/W-01 | R/W-00 |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
29-28 | FILTER2_KCOMP _SEL | R/W | 00 | Selects KComp value routed to Filter 2 Module 0 = KComp 0 Value Selected (Default) 1 = KComp 1 Value Selected 2 = KComp 2 Value Selected |
27-26 | FILTER1_KCOMP _SEL | R/W | 00 | Selects KComp value routed to Filter 1 Module 0 = KComp 0 Value Selected (Default) 1 = KComp 1 Value Selected 2 = KComp 2 Value Selected |
25-24 | FILTER0_KCOMP _SEL | R/W | 00 | Selects KComp value routed to Filter 0 Module 0 = KComp 0 Value Selected (Default) 1 = KComp 1 Value Selected 2 = KComp 2 Value Selected |
23-19 | Reserved | R | 0 0000 | |
18 | FILTER2_FFWD _SEL | R/W | 0 | Configures Feedforward value routed to Filter 2 Module 0 = Filter 0 Output Selected (Default) 1 = Filter 1 Output Selected |
17 | FILTER1_FFWD _SEL | R/W | 0 | Configures Feedforward value routed to Filter 1 Module 0 = Filter 0 Output Selected (Default) 1 = Filter 2 Output Selected |
16 | FILTER0_FFWD _SEL | R/W | 0 | Configures Feedforward value routed to Filter 0 Module 0 = Filter 1 Output Selected (Default) 1 = Filter 2 Output Selected |
15-14 | Reserved | R | 00 | |
13-12 | FILTER2_PER _SEL | R/W | 00 | Selects source of switching cycle period for Filter 2 Module 0 = DPWM 0 Switching Period (Default) 1 = DPWM 1 Switching Period 2 = DPWM 2 Switching Period 3 = DPWM 3 Switching Period |
11-10 | FILTER1_PER _SEL | R/W | 00 | Selects source of switching cycle period for Filter 1 Module 0 = DPWM 0 Switching Period (Default) 1 = DPWM 1 Switching Period 2 = DPWM 2 Switching Period 3 = DPWM 3 Switching Period |
9-8 | FILTER0_PER _SEL | R/W | 00 | Selects source of switching cycle period for Filter 0 Module 0 = DPWM 0 Switching Period (Default) 1 = DPWM 1 Switching Period 2 = DPWM 2 Switching Period 3 = DPWM 3 Switching Period |
7-6 | Reserved | R | ||
5-4 | FILTER2_FE_SEL | R/W | 10 | Selects which Front End Module provides data for Filter 2 Module 0 = Front End Module 0 provides data to Filter 1 = Front End Module 1 provides data to Filter 2 = Front End Module 2 provides data to Filter (Default) |
3-2 | FILTER1_FE_SEL | R/W | 01 | Selects which Front End Module provides data for Filter 1 Module 0 = Front End Module 0 provides data to Filter 1 = Front End Module 1 provides data to Filter (Default) 2 = Front End Module 2 provides data to Filter |
1-0 | FILTER0_FE_SEL | R/W | 00 | Selects which Front End Module provides data for Filter 0 Module 0 = Front End Module 0 provides data to Filter (Default) 1 = Front End Module 1 provides data to Filter 2 = Front End Module 2 provides data to Filter |