SNIU028D February 2016 – September 2020 UCD3138 , UCD3138064 , UCD3138064A , UCD3138128 , UCD3138A , UCD3138A64
As mentioned earlier, the DPWM module generates signals to generate a sample trigger in the Error ADC in the Front End. The DPWMs can also provide oversampling function in co-ordination with the sample triggers. The SAMP_TRIG1_OVERSAMPLE bit field permits oversampling of 2, 4, and 8 samples in the Front End. The samples are equally distributed in time, starting at the start of the period, and with the last sample at the Sample Trigger 1 point.
The values are:
Sample trigger 1 can be used either to trigger a complete cycle with Front End and Filter, or it can be used for spatial averaging. See Chapter 3, especially Section 3.2.5.