SNIU028D February 2016 – September 2020 UCD3138 , UCD3138064 , UCD3138064A , UCD3138128 , UCD3138A , UCD3138A64
Here the sequencer is synchronized to the start of an external trigger. At the end of the conversion sequence, when the maximum number of conversions has occurred, the sequencer performs only a single sweep of conversions.
Requirement: Automatically convert 4 voltages (V1/V2/V3/V4) every 100us synchronized to an external trigger. In this example, the maximum number of conversions is set to 3 and the sequence select registers are set as follows:
Bits | Field Name | Channel Select Value | |
---|---|---|---|
SEQCHSEL0 | 4:0 | SEQ00 | V1 |
9:5 | SEQ01 | V2 | |
14:10 | SEQ02 | V3 | |
SEQCHSEL1 | Bits | Field Name | Channel Select Value |
4:0 | SEQ03 | V4 | |
9:5 | SEQ04 | X | |
14:10 | SEQ05 | X |