SNIU028D February 2016 – September 2020 UCD3138 , UCD3138064 , UCD3138064A , UCD3138128 , UCD3138A , UCD3138A64
Address FFF7F600
20 | 19 | 18 | 17 | 16 |
PRC_CALL | GRP_CMD | PEC_ENA | EXT_CMD | CMD_ENA |
R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
BYTE_COUNT | SLAVE_ADDR | RW |
R/W-0000 0000 | R/W-000 0000 | R/W-0 |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
20 | PRC_CALL | R/W | 0 | Master Process Call Message Enable 0 = Default state for all messages besides Process Call message (Default) 1 = Enables transmission of Process Call message |
19 | GRP_CMD | R/W | 0 | Master Group Command Message Enable 0 = Default state for all messages besides Group Command message (Default) 1 = Enables transmission of Group Command message |
18 | PEC_ENA | R/W | 0 | Master PEC Processing Enable 0 = Disables PEC processing (Default) 1 = Enables PEC byte transmission/reception |
17 | EXT_CMD | R/W | 0 | Master Extended Command Code Enable 0 = Use 1 byte for Command Code (Default) 1 = Use 2 bytes for Command Code |
16 | CMD_ENA | R/W | 0 | Master Command Code Enable 0 = Disables use of command code on Master initiated messages (Default) 1 = Enables use of command code on Master initiated messages |
15-8 | BYTE_COUNT | R/W | 0000 0000 | Indicates number of data bytes transmitted in current message. Byte count does not include any device addresses, command words or block lengths in block messages. In block messages, the PMBus Interface automatically inserts the block length into the message based on the byte count setting. The firmware only needs to load the address, command words and data to be transmitted. PMBus Interface supports byte writes up to 255 bytes. |
7-1 | SLAVE_ADDR | R/W | 000 0000 | Specifies the address of the slave to which the current message is directed towards. |
0 | RW | R/W | 0 | Indicates if current Master initiated message is read operation or write operation. 0 = Message is a write transaction (data from Master to Slave) (Default) 1 = Message is a read transaction (data from Slave to Master) |