SNIU028D February 2016 – September 2020 UCD3138 , UCD3138064 , UCD3138064A , UCD3138128 , UCD3138A , UCD3138A64
Address 00020040
8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CONSTANT _CUR | CONSTANT _PWR | CONSTANT _VOLT | CC_TO_CV _INT | CV_TO_CC _INT | CC_TO_CP _INT | CP_TO_CC _INT | CP_TO_CV _INT | CV_TO_CP _INT |
R-0 | R-0 | R-0 | R-0 | R-0 | R-0 | R-0 | R-0 | R-0 |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
8 | CONSTANT_CUR | R | 0 | Constant Current Mode Indication 0 = Constant Current Mode not enabled 1 = Constant Current Mode enabled |
7 | CONSTANT_PWR | R | 0 | Constant Power Mode Indication 0 = Constant Power Mode not enabled 1 = Constant Power Mode enabled |
6 | CONSTANT _VOLT | R | 0 | Constant Voltage Mode Indication 0 = Constant Voltage Mode not enabled 1 = Constant Voltage Mode enabled |
5 | CC_TO_CV_INT | R | 0 | Constant Current Mode to Constant Voltage Mode latched status, cleared on read 0 = No transition from Constant Current to Constant Voltage detected 1 = Transition from Constant Current to Constant Voltage detected |
4 | CV_TO_CC_INT | R | 0 | Constant Voltage Mode to Constant Current Mode latched status, cleared on read 0 = No transition from Constant Voltage to Constant Current detected 1 = Transition from Constant Voltage to Constant Current detected |
3 | CC_TO_CP_INT | R | 0 | Constant Current Mode to Constant Power Mode latched status, cleared on read 0 = No transition from Constant Current to Constant Power detected 1 = Transition from Constant Current to Constant Power detected |
2 | CP_TO_CC_INT | R | 0 | Constant Power Mode to Constant Current Mode latched status, cleared on read 0 = No transition from Constant Power to Constant Current detected 1 = Transition from Constant Power to Constant Current detected |
1 | CP_TO_CV_INT | R | 0 | Constant Power Mode to Constant Voltage Mode latched status, cleared on read 0 = No transition from Constant Power to Constant Voltage detected 1 = Transition from Constant Power to Constant Voltage detected |
0 | CV_TO_CP_INT | R | 0 | Constant Voltage Mode to Constant Power Mode latched status, cleared on read 0 = No transition from Constant Voltage to Constant Power detected 1 = Transition from Constant Voltage to Constant Power detected |