Download and install the
DS320PR810 Profile Updater.
Connect a USB2ANY Interface
Adapter or Aardvark I2C Host Adapter to the desired DS320PR810 and PC.
Open SigCon Architect and click
the Configuration tab below the DS320PR8xx profile on the left, as shown
below.
.
Click the Auto Detect
button to detect the device and SMbus addresses.
Ensure the correct interface
adapter is selected below the interface drop-down menu (USB2ANY or Aardvark).
Then click Apply. The user will see the other tabs under the DS320PR8xx
profile become un-greyed. Click the desired tab to begin programming the
device.
Descriptions of each tab is
listed below:
Low Level Page:
Individual register access to the lowest level of the device. Can be
used to change specific settings, or to verify changes from the
high-level page have taken effect.
EEPROM Page: When in I2C
primary mode, upon boot up the redriver will load the settings stored in
its EEPROM. The user can configure those settings here.
High Level Page: Main
page used to change EQ settings of the device and to see the active
status of each channel
Eye Height Page: Performs
a sweep of all CTLE settings for the desired channel and displays eye
height for each settings. This can assist in choosing an optimal CTLE
setting for your system.
System Page: Allows the
user to input pre and post channel losses of their system, and provides
a recommended CTLE index value for each PCIe transmitter preset.