There were no functional failures at any irradiation level. All tested parameters remained within the data sheet specifications for all devices, with dosage up to 1 × 1013 n/cm2. Noticeable shifts in input offset voltage were recorded for some units dosed to 5 × 1012 n/cm2 and to 1 × 1013 n/cm2. All other tested parameters were observed to be within the test limits of the ATE program for the device, and as a result, within the data sheet specifications. While the gain-bandwidth product appeared to shift for some units, this particular test serves as a functional screen for gross outliers rather than a precise parametric measurement, and thus these results are not of significant concern.