SNVA966 July 2020 – MONTH LP8864-Q1 , LP8864S-Q1 , LP8866-Q1 , LP8866S-Q1
If the LP886XX-Q1 device is enabled while a valid external SYNC clock is running and BST_SYNC stops or changes to an invalid frequency (< 75 kHz), the LP886XX-Q1 defaults to internal clock frequency selected by BST_FSET resistor and BSTSYNC_STATUS bit will be set. If BST_SYNC input is held high, spread spectrum is enabled. If the SYNC input is held low, the spread spectrum is disabled.