SNVK008 April   2024 TPS7H4011-SP

 

  1.   1
  2.   2
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Unbiased
      2. 2.3.2 Biased
    4. 2.4 Biased Test Configuration and Condition
  6. 3TI Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 Specification Compliance Matrix
      1. 3.2.1 Electrical Characteristics
  7. 4Applicable and Reference Documents
    1. 4.1 Applicable Documents
    2. 4.2 Reference Documents
  8.   A Appendix A: HDR Results Report at 100krad(Si)

Biased Test Configuration and Condition

HDR devices were stressed at 100 krad(Si) for biased and unbiased conditions.

Table 2-1 HDR : 100-krad(Si)/s Biased Device Information
Total Samples: 5
Exposure Levels
100 krad(Si)
#5, #6, #7, #8, #9
Table 2-2 HDR : 100-krad(Si)/s Unbiased Device Information
Total Samples: 5
Exposure Levels
100 krad(Si)
#10, #11, #12, #13, #14