SPRABI1D January 2018 – July 2022 66AK2E05 , 66AK2G12 , 66AK2H06 , 66AK2H12 , 66AK2H14 , 66AK2L06 , AM5K2E02 , AM5K2E04 , SM320C6678-HIREL , TMS320C6652 , TMS320C6654 , TMS320C6655 , TMS320C6657 , TMS320C6670 , TMS320C6671 , TMS320C6672 , TMS320C6674 , TMS320C6678
All address and command nets between the DSP and UDIMM must be referenced to a solid ground or solid power plane — the best option would be a solid ground plane. The entire address bus and/or command nets can be referenced to the DVDD15 power plane as long a sufficient distributed decoupling is located near the endpoints and vias of all routes to provide a low-impedance current return path. All address and command nets routing from the DSP to the UDIMM socket must be adjacent to the referenced plane.
The address bus and command nets between the DSP and UDIMM should be routed away from the data bus and respective nets.