SPRAC21A June 2016 – June 2019 OMAP-L132 , OMAP-L138 , TDA2E , TDA2EG-17 , TDA2HF , TDA2HG , TDA2HV , TDA2LF , TDA2P-ABZ , TDA2P-ACD , TDA2SA , TDA2SG , TDA2SX , TDA3LA , TDA3LX , TDA3MA , TDA3MD , TDA3MV
In normal mode, 7 bit ECC are computed for 32 bit word whereas in narrow mode, 6 bit ECC is computed for 16bit word. Non availability of read-modify-write support in ECC means that when a ECC sub-quanta (<32bit writes for normal and <16bit writes for narrow) writes happen to EMIF, the ECC does not get computed properly as EMIF does not read back the whole 32/16 bit to compute the ECC for the non-modified portion of the word. This results in below careabouts to be followed while programming.