SPRUHM9H October 2014 – May 2024 TMS320F28075 , TMS320F28075-Q1 , TMS320F28076
Based on a given analog input voltage, the expected digital conversion is given in Table 10-2. Fractional values are truncated.
Analog Input | Digital Result |
---|---|
when ADCINy ≤ VREFLO | ADCRESULTx = 0 |
when VREFLO < ADCINy < VREFHI | ADCRESULTx = 4096 |
when ADCINy ≥ VREFHI | ADCRESULTx = 4095 |