SPRUI78D March 2019 – January 2022 TMS320F28075 , TMS320F28075-Q1 , TMS320F28076 , TMS320F28374D , TMS320F28374S , TMS320F28375D , TMS320F28375S , TMS320F28375S-Q1 , TMS320F28376D , TMS320F28376S , TMS320F28377D , TMS320F28377D-Q1 , TMS320F28377S , TMS320F28377S-Q1 , TMS320F28378D , TMS320F28378S , TMS320F28379D , TMS320F28379D-Q1 , TMS320F28379S
A Self-Test-Library (STL) was developed for the Control-Law-Accelerator (CLA) and is described in detail in the C2000 CLA self-test library. The SDF (Software Delivery Form) file delivered in the CSP (Compliance Support Package) must be reviewed specifically for the MD5 Signature that apply to each of the source files used to create the Self Test Library. In order to ensure that the required diagnostic coverage based metrics are achieved, the source must not modified in anyway and is expected to be used as is. Violating this condition will result in a potential failure in the operation of the CLA_STL and it may not meet the required safety requirements.
The CLA-STL was independently assessed and found to be suitable for being integrated into safety-related systems up to SIL 3 according IEC 61508:2010 and ASIL D according to ISO 26262:2018. The CLA-STL represents a safety mechanism with the capability to detect permanent faults of the Control Law Accelerator (CLA).
The CLA-STL is developed using TI internal software development process specification which targets software development flows for baseline, automotive and functional safety. (for functional safety, specifically, the target is systematic capability compliance with the IEC 61508 and ISO 26262 standards).
This TI internal process specification describes the contents of required deliverables during each phase of software development process. By adhering to this specification and complying with the underlying processes, including methods and techniques (IEC 61508-3, ISO 26262-6), which are comprehended in the work-products, it is ensured that a TI SW/FW development achieves a systematic capability of ASIL-D (ISO 26262-6) and SIL-3 (IEC 61508-3).