SPRUIM6A October 2018 – November 2020
The following modifications are needed for PHY0 (U52) to convert it for use with the MII interface.
Clock modification – The clock resistors for U52 is on the bottom of the board. Remove R452 and install a zero ohm resistor for R453.
Configuration modification – The circuit for U52 is on the top of the board. Add three zero ohm 0402 resistors to R445, R290, and R444 to configure the interface for MII.