SPRUIX1B October 2022 – April 2024 TMS320F2800132 , TMS320F2800133 , TMS320F2800135 , TMS320F2800137
For SPIBRR = 3 to 127:
For SPIBRR = 0, 1, or 2:
where:
LSPCLK = Low-speed peripheral clock frequency of the device
SPIBRR = Contents of the SPIBRR in the master SPI device
To determine what value to load into SPIBRR, you must know the device system clock (LSPCLK) frequency (that is device-specific) and the baud rate at which you are operating.