SPRZ171T December   2004  – September 2020 SM320F2801-EP , SM320F2808-EP , TMS320F2801 , TMS320F2801-Q1 , TMS320F28015 , TMS320F28016 , TMS320F28016-Q1 , TMS320F2802 , TMS320F2802-Q1 , TMS320F2806 , TMS320F2806-Q1 , TMS320F2808 , TMS320F2808-Q1 , TMS320F2809 , TMS320F2809-Q1

 

  1. 1Introduction
  2. 2Device and Development Tool Support Nomenclature
  3. 3Device Markings
  4. 4Silicon Change Overview
  5. 5Usage Notes and Known Design Exceptions to Functional Specifications
    1. 5.1 Usage Notes
      1. 5.1.1 PIE: Spurious Nested Interrupt After Back-to-Back PIEACK Write and Manual CPU Interrupt Mask Clear Usage Note
    2. 5.2 Known Design Exceptions to Functional Specifications
      1.      Advisory
      2.      Advisory
      3.      Advisory
      4.      Advisory
      5.      Advisory
      6.      Advisory
      7.      Advisory
      8.      Advisory
      9.      Advisory
      10.      Advisory
      11.      Advisory
      12.      Advisory
      13.      Advisory
      14.      Advisory
      15.      Advisory
      16.      Advisory
      17.      Advisory
      18.      Advisory
      19.      Advisory
      20.      Advisory
      21.      Advisory
      22.      Advisory
  6. 6Documentation Support
  7. 7Trademarks
  8. 8Revision History

Advisory

eCAN: Unexpected Cessation of Transmit Operation

Revision(s) Affected

0, A on F2809 silicon

0, A on C280x silicon

0, A, B, C on F2801, F2802, F2806, F2808, and F28016 silicon

Details

In rare instances, the cessation of message transmission from the eCAN module has been observed (while the receive operation continues normally). This anomalous state may occur without any error frames on the bus.

Workaround(s)