SPRZ408D June 2014 – June 2021 AM4372 , AM4376 , AM4377 , AM4378 , AM4379
DSS: DSS Smart Standby May Cause Synchronization Issues
1.1, 1.2
Enabling DSS Smart Standby may cause synchronization issues with the PRCM, which may render the DSS inoperable.
DSS MIDLE_MODE = 2 (SmartStandby) should not be used because of possible synchronization issues.
The following sequence must be followed to avoid synchronization issues.
During DSS initialization
During DSS Disable