SPRZ507C January 2023 – July 2024 TMS320F2800152-Q1 , TMS320F2800153-Q1 , TMS320F2800154-Q1 , TMS320F2800155 , TMS320F2800155-Q1 , TMS320F2800156-Q1 , TMS320F2800157 , TMS320F2800157-Q1
LCM: Consecutive Reset Cycles can Cause False LCM Compare Error
0, A, B
When SYSCLKDIVSEL[PLLSYSCLKDIV] is set to /1 (0h), consecutive reset cycles (XRSn) can cause a false Lockstep Compare Module (LCM) compare error.
After reset, check if the compare error flag (LCM_STATUS.CMP_FAIL) is set from the previous reset assertion. If yes, clear the flag first before setting the LCM Compare Enable (LCM_CONTROL.CMPEN).