SWCU185G January 2018 – June 2024 CC1312PSIP , CC1312R , CC1352P , CC1352R , CC2642R , CC2642R-Q1 , CC2652P , CC2652PSIP , CC2652R , CC2652RB , CC2652RSIP , CC2662R-Q1
Each channel implements 15 different channel actions. They are categorized as one-shot and continuous:
Table 20-30 lists the 15 channel actions.
Index | Channel Action | Category |
---|---|---|
0 | Disable channel | One-shot |
1 | Set on capture, and then disable channel | One-shot |
2 | Clear on zero, toggle on compare, and then disable channel | One-shot |
3 | Set on zero, toggle on compare, and then disable channel | One-shot |
4 | Clear on compare, and then disable channel | One-shot |
5 | Set on compare, and then disable channel | One-shot |
6 | Toggle on compare, and then disable channel | One-shot |
7 | Pulse on compare, and then disable channel | One-shot |
8 | Period and pulse width measurement | Continuous |
9 | Set on capture repeatedly | Continuous |
10 | Clear on zero, toggle on compare repeatedly | Continuous |
11 | Set on zero, toggle on compare repeatedly | Continuous |
12 | Clear on compare repeatedly | Continuous |
13 | Set on compare repeatedly | Continuous |
14 | Toggle on compare repeatedly | Continuous |
15 | Pulse on compare repeatedly | Continuous |
After configuration, the channel requests updates of enabled event outputs according to the channel action description in Table 20-30. There are three channel actions that require further description.