SWCU192 November 2021 CC1312R7 , CC1352P7 , CC2652P7 , CC2652R7
The Sensor Controller runs at 24 MHz in active mode and at 2 MHz in low-power mode. All Sensor Controller instructions use 2 clock cycles, with the following exceptions:
in
,
out
,
iobset
,
iobclr
, and
iobtst
) to ADI and DDI registers, which go through multi-cycle interfaces. These registers are related to analog peripherals and oscillators.
wev0
,
wev1
, and
sleep