SWCU193A April 2023 – August 2024 CC2340R2 , CC2340R5 , CC2340R5-Q1
To set up the channel filters in LGPT follow these steps:
When configuring the channel filter make sure the channel filter period is not shorter than the timer clock period. That is,
(Channel filter clock period) × (CHFILT.LOAD) > timer clock period.
If this is not satisfied capture events can be missed.