SWCU193A April 2023 – August 2024 CC2340R2 , CC2340R5 , CC2340R5-Q1
SYSTIM is a 34-bit timer running at a resolution of 250ns with a low range (about 1.2hr) but high precision (of 250ns) that can be used by both the RF-Core and the system CPU. SYSTIM follows the RTC (Chapter 12) and can only be used in device active state. The SYSTIM synchronizes with the RTC. Synchronization is done during start-up and continuously during the active state. When the device goes from standby, reset, or shutdown to active the value of the RTC time is loaded to SYSTIM with a resolution of 250ns.
SYSTIM has five channels: