SWRZ073C May 2017 – May 2021 IWR1642
Return Loss Measurement on TX: S11 < –9dB, RX S11 < –6.5dB (Accepted Value of < –10dB)
IWR1642 ES1.0
The return loss measurement on TX S11 is < –9dB and the return loss measurement on RX S11 is < –6.5dB. The accepted value is < –10dB.
None. TI expects to provide an update along with the next silicon revision.