SWRZ074C May 2017 – May 2021 IWR1443
ESM Group2 Interrupt (VIM Compare Error), which is Mapped to FIQ Line, is Active when Control is Passed to Application
IWR1443 ES1.0 and IWR1443 ES2.0
Compare Error is always present when the control is passed to the application due to a missing configuration in device bootloader.
The Application is expected to clear this error immediately on start up.