SWRZ090C January   2020  – October 2023 AWR2243

 

  1.   1
  2. 1Introduction
  3. 2Device Nomenclature
  4. 3Device Markings
  5. 4Advisory to Silicon Variant / Revision Map
  6. 5Known Design Exceptions to Functional Specifications
    1.     MSS#37
    2.     MSS#44A
    3. 5.1 MSS#50
    4. 5.2 MSS#51
    5.     ANA#08A
    6. 5.3 ANA#11A
    7. 5.4 ANA#12A
    8.     ANA#13B
    9.     ANA#18B
    10.     ANA#21A
    11.     ANA#22A
    12.     ANA#23
    13.     ANA#24
    14.     ANA#25
    15. 5.5 ANA#27A
    16.     ANA#28
    17.     ANA#53
  7.   Trademarks
  8.   Revision History

Revision History

Changes from January 15, 2022 to October 15, 2023 (from Revision B (January 2022) to Revision C (October 2023))

  • (Advisory to Silicon Variant/Revision Map): Updated/revised ANA#53 advisory, all silicon revisions in "Analog/Millimeter Wave" categoryGo
  • ANA#27A: Updated/revised the title, description and the workaround for better understanding.Go
  • ANA#53: Added new advisory addressing the issue of upper frequency limitation of the VCO Go

Changes from August 15, 2020 to January 15, 2022 (from Revision A (August 2020) to Revision B (January 2022))

  • (Global): Shift to more inclusive terminology made in terms of "Master/slave" keywordsGo
  • (Advisory to Silicon Variant/Revision Map): Added MSS#44A, MSS#50 and MSS#51 advisories, all silicon revisions in "Main Subsytems"Go
  • (Advisory to Silicon Variant/Revision Map): Updated/Revised ANA#13B, ANA#18B, ANA#21A advisories, all silicon revisions in "Analog/Millimeter Wave" categoryGo
  • Added MSS#44A:SYNC IN input pulse wider than 4usec can cause a FRC lockstep errorGo
  • ANA#13B: Updated/Revised the Description and Errata Title to report higher phase mismatch variation for TX3/TX2 combinationGo
  • ANA#18B: Updated/Revised the Description to include 18 and 18.75Msps sampling rates; Rephrased the WorkaroundGo
  • ANA#21A: Rephrased the Description and WorkaroundGo