SWRZ102B November 2021 – October 2023 AWR2944
PRODUCTION DATA
Measurement Data Output (MDO) software marker inserted at FIFO threshold location other than for Sniffer 0 is not sent out and is bound to get missed.
AWR294x ES1.0 Only
Measurement Data Output (MDO) is used to capture the transactions on the bus connected from different interfaces of the AWR294x device and transmit outside over LVDS (4-data lanes). MDO is comprised of a sniffer, FIFO, and an aggregator. The corresponding sniffer module sniffs a bus interface and accumulates data in the FIFO. When a FIFO threshold is reached, the data is sent out to the aggregator as a burst transfer.
An MDO source can also inject a marker indicator along with its data for tracking or other related purpose. Now, if a marker is inserted such that it is a part of the last element of the FIFO threshold location, it is bound to get missed.
This happens only when a sniffer other than Sniffer 0 is used for transfer.
The following two workarounds can be used to ensure the inserted maker is registered without fail :