TIDT202 September   2020

 

  1.   Description
  2. 1Test Prerequisites
    1. 1.1 Design Requirements
    2. 1.2 Required Equipment
    3. 1.3 Dimensions
  3. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Load Regulation
    4. 2.4 Thermal Images
  4. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple
    3. 3.3 Load Transients
    4. 3.4 Start-up Sequence
    5. 3.5 Undervoltage Protection
    6. 3.6 Thermal Management

Efficiency Data

Efficiency data is shown in the following table.

VIN (V)

IIN (A)

VPA_BUS (V)

IPA_BUS (A)

VPB_BUS (V)

IPB_BUS (A)

Eff

13.499

0.0290

5.1586

0.0000

5.1586

0.0000

0.00%

13.502

0.2270

5.1616

0.2492

5.1616

0.2484

83.80%

13.502

0.4275

5.1678

0.4989

5.1678

0.4981

89.26%

13.507

0.6268

5.1726

0.7484

5.1727

0.7477

91.41%

13.500

0.8279

5.1771

0.9983

5.1772

0.9974

92.44%

13.503

1.0308

5.1818

1.2483

5.1819

1.2499

93.01%

13.505

1.2345

5.1868

1.4975

5.1870

1.4999

93.25%

13.499

1.4413

5.1922

1.7474

5.1923

1.7495

93.32%

13.500

1.6483

5.1976

1.9970

5.1980

1.9992

93.35%

13.500

1.8588

5.2028

2.2470

5.2035

2.2489

93.22%

13.503

2.0742

5.2063

2.4994

5.2070

2.5016

92.97%

13.496

2.2874

5.2023

2.7491

5.2030

2.7516

92.70%

13.498

2.5020

5.1980

2.9992

5.1987

3.0016

92.37%