TIDT228 October   2022

 

  1.   Description
  2.   Features
  3.   Applications
  4. 1Specifications
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Dimensions
  5. 2Testing and Results
    1. 2.1 Standby Power Consumption
    2. 2.2 Efficiency Graphs
    3. 2.3 Thermal Images
    4. 2.4 Bode Plots
    5. 2.5 Conducted EMI
  6. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple
    3. 3.3 Load Transients
    4. 3.4 Start-Up

Thermal Images

All images captured with the unit under test (UUT) were enclosed in a 30 cm × 45 cm × 20 cm plexiglass box, 25ºC ambient, after a 30-minute warm up. The input voltage was 115 VAC, 60 Hz.

GUID-20220815-SS0I-T9RF-2NRZ-VL9R4TK0LZCP-low.jpgFigure 2-9 20-V Output With 3-A Load, Top View
GUID-20220815-SS0I-L8NR-THTV-JFSM94CHQQZV-low.jpgFigure 2-11 15-V Output With 4-A Load, Top View
GUID-20220815-SS0I-XBHF-TLKH-ZC8WVSJJWH9L-low.jpgFigure 2-13 9-V Output With 6-A Load, Top View
GUID-20220815-SS0I-7WM8-TXGX-JH4XFZ9RHNF2-low.jpgFigure 2-15 5-V Output With 6-A Load, Top View
GUID-20220815-SS0I-DRVM-285J-S7PD1QCLDTN8-low.jpgFigure 2-10 20-V Output With 3-A Load, Bottom View
GUID-20220815-SS0I-L9QP-LJPN-1P4STRBBLZR3-low.jpgFigure 2-12 15-V Output With 4-A Load, Bottom View
GUID-20220815-SS0I-MBH7-WD6R-DMG62QPJV6KG-low.jpgFigure 2-14 9-V Output With 6-A Load, Bottom View
GUID-20220815-SS0I-LLT4-VM1X-L5RLHWNZGQG0-low.jpgFigure 2-16 5-V Output With 6-A Load, Bottom View