Complete the following for bode loop testing:
- Cut the connection from R15 to TP3 (24 V). This cut is bridged with 49.9 Ω and
is called R100.
- On the PCB, cut the TP8 connection to U2–13. R10 (power good pullup) is not
populated.
- Populate TP8 with a green through-hole test point (Keystone 5116) and tie to a
connection between R100 and R115. TP8 becomes a signal injection point
for the bode plot.
- Use a network analyzer such as the Bode 100 from Omricon Lab with the
following:
- V1 measured between injection point TP8 and ground TP10
- V2 measured between VOUT TP3 and ground
- Actual signal injection between TP8 and TP3