Load Transients
Load transient response is shown in the following figures.
Figure 3-6
Output Load Step Response, 1.00-A to 2.10-A Load Step, 200 mV/div, 1 A/div, 500 µs/div,
Slew Rate = 250 mA/µs, Measured –220 mV to +213 mV
Figure 3-7
Output Load Step Response, 200-mA to 1.90-A Load Step, 200 mV/div, 1 A/div, 500 µs/div, Slew Rate = 250 mA/µs, Measured –327 mV to +313 mV