Overcurrent Protection

Over current protection is shown in Figure 3-16. The test condition is 400Vin, 13.5Vout, room temperature.

CH1: Current Transformer sensed current

CH2: Overcurrent protection (OCP) trip flag

CH3: Differential voltage of Transformer Primary winding

CH4: Current of Transformer Primary winding

PMP41078 Over-Current ProtectionFigure 3-16 Over-Current Protection