ZHCSAB6E October 2012 – May 2018 BQ27545-G1
PRODUCTION DATA.
The host system should write this value to inform the device that new data is ready for programming into the specified data flash class and block.
UNSEALED Access: This byte contains the checksum on the 32 bytes of block data read or written to data flash. The least-significant byte of the sum of the data bytes written must be complemented ( [255 – x], for x the 8-bit summation of the BlockData() (0x40 to 0x5F) on a byte-by-byte basis.) before being written to 0x60.
SEALED Access: This byte contains the checksum for the 32 bytes of block data written to Manufacturer Info Block A. The least-significant byte of the sum of the data bytes written must be complemented ( [255 – x], for x the 8-bit summation of the BlockData() (0x40 to 0x5F) on a byte-by-byte basis.) before being written to 0x60.