SUPPLY VOLTAGE |
V(IN) |
Operating input voltage |
|
4.2 |
|
60 |
V |
V(PORR) |
Internal POR threshold, rising |
|
3.9 |
4 |
4.1 |
V |
V(PORHys) |
Internal POR hysteresis |
|
250 |
275 |
300 |
mV |
IQ(ON) |
Supply current |
Enabled: V(SHDN) = 2 V |
190 |
300 |
390 |
µA |
IQ(OFF) |
V(SHDN) = 0 V |
11 |
20 |
33 |
µA |
I(VINR) |
Reverse input supply current |
V(IN) = –60 V, V(OUT) = 0 V |
|
|
66 |
µA |
V(OVC) |
Overvoltage clamp |
V(IN) > 42 V, TPS26602 only |
36 |
37.5 |
40 |
V |
UNDERVOLTAGE LOCKOUT (UVLO) INPUT |
V(IN_UVLO) |
Factory set V(IN) undervoltage trip level |
V(IN) rising, V(UVLO) = 0 V |
14.25 |
14.9 |
15.75 |
V |
V(IN) falling, V(UVLO) = 0 V |
13.25 |
13.8 |
14.75 |
V(SEL_UVLO) |
Internal UVLO select threshold |
|
180 |
200 |
240 |
mV |
V(UVLOR) |
UVLO threshold voltage, rising |
|
1.175 |
1.19 |
1.225 |
V |
V(UVLOF) |
UVLO threshold voltage, falling |
|
1.08 |
1.1 |
1.125 |
V |
I(UVLO) |
UVLO input leakage current |
0 V ≤ V(UVLO) ≤ 60 V |
–100 |
0 |
100 |
nA |
LOW IQ SHUTDOWN (SHDN) INPUT |
V(SHDN) |
Output voltage |
I(SHDN) = 0.1 µA |
2 |
2.7 |
3.4 |
V |
V(SHUTF) |
SHDN threshold voltage for low IQ shutdown, falling |
|
0.55 |
0.76 |
0.94 |
V |
I(SHDN) |
Leakage current |
V(SHDN) = 0.4 V |
–10 |
|
|
µA |
OVERVOLTAGE PROTECTION (OVP) INPUT |
V(IN_OVP) |
Factory set V(IN) overvoltage trip level |
V(IN) rising, V(OVP) = 0 V |
31 |
32.6 |
34 |
V |
V(IN) falling, V(OVP) = 0 V |
28.5 |
30.3 |
31.5 |
V(SEL_OVP) |
Internal OVP select threshold |
|
180 |
200 |
240 |
mV |
V(OVPR) |
Overvoltage threshold voltage, rising |
|
1.17 |
1.19 |
1.225 |
V |
V(OVPF) |
Overvoltage threshold, falling |
|
1.085 |
1.1 |
1.125 |
V |
I(OVP) |
OVP input leakage current |
0 V ≤ V(OVP) ≤ 4 V |
–100 |
0 |
100 |
nA |
OVPMAX |
Maximum external OVP setting |
TPS26600, TPS26601 only |
|
|
55 |
V |
OUTPUT RAMP CONTROL (dVdT) |
I(dVdT) |
dVdT charging current |
V(dVdT) = 0 V |
4 |
4.7 |
5.5 |
µA |
R(dVdT) |
dVdT discharging resistance |
V(SHDN) = 0 V, with I(dVdT) = 10 mA sinking |
|
14 |
|
Ω |
GAIN(dVdT) |
dVdT to OUT gain |
V(OUT)/V(dVdT) |
23.75 |
24.6 |
25.5 |
V/V |
CURRENT LIMIT PROGRAMMING (ILIM) |
V(ILIM) |
ILIM bias voltage |
|
|
1 |
|
V |
I(OL) |
Overload current limit |
R(ILIM) = 120 kΩ, V(IN) – V(OUT) = 1 V |
0.085 |
0.1 |
0.115 |
A |
R(ILIM) = 12 kΩ, V(IN) – V(OUT) = 1 V |
0.95 |
1 |
1.05 |
R(ILIM) = 8 kΩ, V(IN) – V(OUT) = 1 V |
1.425 |
1.5 |
1.575 |
R(ILIM) = 5.36 kΩ, V(IN) – V(OUT) = 1 V |
2.11 |
2.23 |
2.35 |
I(OL_R-OPEN) |
R(ILIM) = OPEN, open resistor current limit (single point failure test: UL60950) |
|
0.055 |
|
I(OL_R-SHORT) |
R(ILIM) = SHORT, shorted resistor current limit (single point failure test: UL60950) |
|
0.095 |
|
I(CB) |
Circuit breaker detection threshold |
R(ILIM) = 120 kΩ, MODE = open |
0.045 |
0.073 |
0.11 |
A |
R(ILIM) = 5.36 kΩ, MODE = open |
2 |
2.21 |
2.4 |
I(SCL) |
Short-circuit current limit |
R(ILIM) = 120 kΩ, V(IN) – V(OUT) = 5 V |
0.08 |
0.1 |
0.12 |
A |
R(ILIM) = 8 kΩ, V(IN) – V(OUT) = 5 V |
1.425 |
1.5 |
1.575 |
R(ILIM) = 5.36 kΩ, V(IN) – V(OUT) = 5 V |
2.11 |
2.23 |
2.35 |
I(FASTRIP) |
Fast-trip comparator threshold |
|
|
1.87 × I(OL) + 0.015 |
|
A |
CURRENT MONITOR OUTPUT (IMON) |
GAIN(IMON) |
Gain factor I(IMON):I(OUT) |
0.1 A ≤ I(OUT) ≤ 2 A |
72 |
78.28 |
85 |
µA/A |
PASS FET OUTPUT (OUT) |
RON |
IN to OUT total ON resistance |
0.1 A ≤ I(OUT) ≤ 2 A, TJ = 25°C |
140 |
150 |
160 |
mΩ |
0.1 A ≤ I(OUT) ≤ 2 A, TJ = 85°C |
|
|
210 |
0.1 A ≤ I(OUT) ≤ 2 A, –40°C ≤ TJ ≤ +125°C |
80 |
150 |
250 |
Ilkg(OUT) |
OUT leakage current in Off state |
V(IN) = 60 V, V(SHDN)= 0 V, V(OUT) = 0 V, sourcing |
|
|
12 |
µA |
V(IN) = 0 V, V(SHDN)= 0 V, V(OUT) = 24 V, sinking |
|
|
11 |
V(IN) = –60 V, V(SHDN)= 0 V, V(OUT) = 0 V, sinking |
|
|
50 |
V(REVTH) |
V(IN) – V(OUT) threshold for reverse protection comparator, falling |
|
–15 |
–10 |
–5 |
mV |
V(FWDTH) |
V(IN) – V(OUT) threshold for reverse protection comparator, rising |
|
85 |
96 |
110 |
mV |
FAULT FLAG (FLT): ACTIVE LOW |
R(FLT) |
FLT pull-down resistance |
V(OVP) = 2 V, I(FLT) = 5 mA sinking |
40 |
85 |
160 |
Ω |
I(FLT) |
FLT input leakage current |
0 V ≤ V(FLT) ≤ 60 V |
–200 |
|
200 |
nA |
THERMAL SHUT DOWN (TSD) |
T(TSD) |
TSD threshold, rising |
|
|
157 |
|
ºC |
T(TSDhyst) |
TSD hysteresis |
|
|
10 |
|
ºC |
MODE |
MODE_SEL |
Thermal fault mode selection |
MODE = 402 kΩ to RTN |
Current limiting with latch |
|
MODE = Open |
Circuit breaker mode with auto-retry |
|
MODE = Open (TPS26601 only) |
Circuit breaker mode with latch |
|
MODE = Short to RTN |
Current limiting with auto-retry |
|