4 修订历史记录
Changes from A Revision (August 2017) to B Revision
- Changed Internal Voltage Reference, Accuracy parameter: added TSSOP package to test conditions of first row and added second row for the WQFN packageGo
- Added TSSOP package to conditions of Internal Reference Voltage Histogram figureGo
- Changed Digital Supply Current vs Temperature figureGo
- Changed Voltage Reference section locationGo
- Changed –3-dB bandwidth value in turbo mode 40 SPS parameter from 26.2 Hz to 17.1 HzGo
- Changed Offset Calibration section locationGo
- Changed FFh to FFFFh in Data Integrity sectionGo
- Changed description of power-on reset procedure in Power-On Reset sectionGo
- Added note to Data Format sectionGo
- Changed first paragraph of Data Integrity sectionGo
- Added Register Data Output with CRC Enabled figureGo
- Changed Conversion Data Output with CRC Enabled and Conversion Data Output with Inverted Data Output Enabled figure captionsGo
- Deleted conversion result from bit CRC[1:0] descriptionGo
- Changed 50 µs to 600 µs and changed (MUX[3:1] = 1110) to (MUX[3:0] = 1110) in Pseudo Code Example sectionGo
- Deleted Power-Supply Ramp Rate sectionGo
- Changed 50 µs to 600 µs in Power-Supply Sequencing sectionGo
Changes from * Revision (May 2017) to A Revision