ZHCSIE3B June 2018 – May 2019 LMZM33606
PRODUCTION DATA.
Many applications benefit from employing an enable divider to establish a customized system UVLO. This can be used for sequencing, to satisfy a system timing requirement, or to reduce the occurrence of deep discharge of a battery power source. Figure 35 shows how to use a resistor divider to set a system UVLO level. An external logic output can also be used to drive the EN pin for system sequencing.
Table 7 lists recommended resistor values for RENT and RENB to adjust the system UVLO voltage. TI recommends to set the system UVLO turn-on threshold to approximately 80% to 85% of the minimum expected input voltage.
UVLO (V) | 6.5 | 10 | 15 | 20 | 25 |
---|---|---|---|---|---|
RENT (kΩ) | 100 | 100 | 100 | 100 | 100 |
RENB (kΩ) | 22.6 | 13.7 | 8.66 | 6.34 | 4.99 |