To obtain optimal performance, the decoupling capacitor from IN to GND (thermal pad) and the output filter capacitors from OUT to GND (thermal pad) should be placed as close as possible to the BQ2407x, with short trace runs to both IN, OUT and GND (thermal pad).
All low-current GND connections should be kept separate from the high-current charge or discharge paths from the battery. Use a single-point ground technique incorporating both the small signal ground path and the power ground path.
The high current charge paths into IN pin and from the OUT pin must be sized appropriately for the maximum charge current in order to avoid voltage drops in these traces
The BQ2407x family is packaged in a thermally
enhanced MLP package. The package includes a thermal
pad to provide an effective thermal contact between
the IC and the printed circuit board (PCB); this
thermal pad is also the main ground connection for
the device. Connect the thermal pad to the PCB
ground connection. Full PCB design guidelines for
this package are provided in the QFN/SON PCB Attachment
Application Note.