ZHCSIU3 September 2018 ADS1235
PRODUCTION DATA.
The ADC has two power-down modes: hardware and software. In both power-down modes, the digital outputs remain driven. The digital inputs must be maintained at VIH or VIL levels (do not float the digital inputs). The internal low-dropout regulator remains on, drawing 25 µA (typical) from DVDD.