4 修订历史记录
Changes from B Revision (April 2019) to C Revision
- Deleted 从文档中删除了 ADS125H01Go
- Changed Device Comparison TableGo
- Added Effective resolution parameter to Electrical Characteristics tableGo
- Added Offset Voltage Long-Term Drift curves to Typical CharacteristicsGo
- Added Gain Long-Term Drift curves to Typical CharacteristicsGo
- Added Internal Reference Voltage Long-Term Drift curve to Typical CharacteristicsGo
- Added Oscillator Frequency Long-Term Drift curve to Typical CharacteristicsGo
- Changed Noise Performance sectionGo
- Added effective resolution and noise-free resolution data in Noise PerformanceGo
- Changed sinc1, sinc3, sinc4, and sinc5 values and footnote in Conversion Latency Time tableGo
- Changed start-conversion delay value from 0 µs to 50 µs in the Start-Conversion Delay sectionGo
- Changed sinc mode values in Calibration Time tableGo
- Changed address 00h default value from xxh to 6xh in Register Map Summary tableGo
- Changed reset value from xxh to 6xh in Device Identification (ID) RegisterGo
Changes from A Revision (January 2019) to B Revision
- Changed 将 ADS125H02 的状态从“预告信息”更改成了“生产数据”Go