ZHCSJ22B October   2017  – July 2019 ISO7041

PRODUCTION DATA.  

  1. 特性
  2. 应用
  3. 说明
    1.     Device Images
      1.      简化应用电路原理图
      2.      电压为 3.3V 时的数据速率与功耗间的关系
  4. 修订历史记录
  5. Device Comparison Table
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Power Ratings
    6. 7.6  Insulation Specifications
    7. 7.7  Safety-Related Certifications
    8. 7.8  Safety Limiting Values
    9. 7.9  Electrical Characteristics 5V Supply
    10. 7.10 Supply Current Characteristics 5V Supply
    11. 7.11 Electrical Characteristics 3.3V Supply
    12. 7.12 Supply Current Characteristics 3.3V Supply
    13. 7.13 Electrical Characteristics 2.5V Supply
    14. 7.14 Supply Current Characteristics 2.5V Supply
    15. 7.15 Switching Characteristics
    16. 7.16 Insulation Characteristics Curves
    17. 7.17 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Refresh Enable
      2. 9.3.2 Electromagnetic Compatibility (EMC) Considerations
    4. 9.4 Device Functional Modes
      1. 9.4.1 Device I/O Schematics
  10. 10Application and Implementation
    1. 10.1 Application Information
      1. 10.1.1 Insulation Lifetime
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
      1. 12.1.1 PCB Material
    2. 12.2 Layout Example
  13. 13器件和文档支持
    1. 13.1 文档支持
      1. 13.1.1 相关文档
    2. 13.2 接收文档更新通知
    3. 13.3 社区资源
    4. 13.4 商标
    5. 13.5 静电放电警告
    6. 13.6 Glossary
  14. 14机械、封装和可订购信息
VDE CSA UL CQC TUV CSA/Sira
Plan to certify according to DIN V VDE V 0884-11:2017- 01 Certified according to IEC 60950-1 and IEC 62368-1 Plan to certify according to UL 1577 Component Recognition Program Plan to certify according to GB4943.1-2011 Plan to certify according to EN 61010-1:2010 (3rd Ed) and EN 60950- 1:2006/A2:2013 Plan to certify for use in intrinsic safety (IS) to IS applications under ATEX and IECEx
Maximum transient isolation voltage,
4242 VPK;
Maximum repetitive peak isolation voltage, 566 VPK;
Maximum surge isolation voltage,
4000 VPK
3000 VRMS insulation per CSA 60950-1-07+A1+A2, IEC 60950-1 2nd Ed.+A1+A2, CSA 62368-1- 14 and IEC 62368-1:2014 370 VRMS (DBQ-16) maximum working voltage (pollution degree 2, material group I)
 
Single protection,
3000 VRMS
Basic insulation, Altitude ≤ 5000 m, Tropical Climate,
250 VRMS maximum working voltage
3000 VRMS insulation per EN 61010-1:2010 (3rd Ed) up to working voltage of 300 VRMS 
3000 VRMS insulation per EN 60950- 1:2006/A2:2013 up to working voltage of 370 VRMS
ATEX: EN 60079-0:2012+A11:2013 and EN 60079-11:2012
IECEx:IEC 60079-0:2011 (6th Ed) and IEC60079-11:2011 (6th Ed)
II 1G Ex ia IIC Ga
Certificate planned Certificate planned Certificate planned Certificate planned Certificate planned Certificate planned